HP-P150PDS  150W Power Supply

HP-P150PDS 150W Power Supply

Product line:Industrial Power SupplyMarket value:0.00

HP-P150PDS is an industrial power supply which is design for the POE switches and POE injectors use. The max output power is 150W with a wide range AC input voltage from 90Vac to 264Vac. The output power is one channel +5V, 4A, and the other channel is -52.5V, 2.6A. The power have the power factor correction, output short circuit protection, output over current protection, Output overvoltage protection, PG monitor signal and Over temperature protection functions, etc. The whole power is design under Safety requirements.

Related products

Another change换一换icon

HP-1230 360W Power Supply

  • Product Brief
  • Customer message

 

Specification Sheet:

Model

Specification

HP-P150PDS

Output Specification

output voltage

V1       52.5V

V2    12.0V

Rated Current

1.65A

6A

Current Range

0---1.65A

0---6A

Ripple Wave

300mVp-p

150mVp-p

Output Accuracy

±2%

±2%

Line Regulation

±1%

±1%

Load Regulation

±1%

±1%

Rating Power

150W

Connect, recover and remain time

500ms , 25ms,   40ms/220VAC

Input Specification

Input Voltage Range

90V---264V AC ;   120V---360V DC

Input Current

1.8A/110V;   1.0A/220V;

Frequency Range

47---63Hz

Efficiency

≥85%  100V

PF data

0.98/220VAC

Impact Current

COLD START :   35A /230VAC

Leakage Current

<3.5mA(AC input to the land)

 

 

 

Protection Features

overload protection

105%-150% Rating Power, auto recovery

overvoltage protection

V1 :  50V-55V

V2: 13.5V-14.5V

Output short circuit protection

The power supply will not broken after long time output short-circuit, remove the short-circuit, the power can recover work.

Over temperature protection

Auto recover

Other Functions:

 

Environmental Features

Working Temperature, Humidity

-20~+50℃@100%LOAD, +60℃@60%LOAD,    20%~90%RH

Storage Temperature, Humidity

-20~+85℃  ,   10%~95%RH

Temperature Range

±0.03%/℃(0-50℃)

Heating Way

Auto

Safety and EMC standard

Safety Standard

UL 60950-2003

High-voltage Holding Test

I/P-O/P:3KV;    I/P-FG:2.0KV;    O/P-FG:500VAC   10mA,1Min

Insulation resistance

I/P-O/P;    I/P-FG;    O/P-FG:500VAC   100M

Other specification

Size

154mm*82mm*24mm

Weight

350±20g

Remark

  1. All the data is recorded by the test with Input 220VAC, rating load, 25 Degree working temperature, 70% Humidity.
  2. Precision include setting error, Line change rate, load change rate, etc.
  3. Ripple Wave Test: Use 30cm cable to connect the power and the load, the load is parallel connected with 0.1uf and 47uf capacitors, use 20M OSC test the load part to get the result.
  4. Line Regulation: Under rating load, the test is based on the low input voltage change to high input voltage.
  5. Load Regulation: The test is based on the change between the 0 Load and 100% load.

 