Protection Features
|
Over-load protection
|
105%-150% Rating Power, auto recovery
|
Over-voltage protection
|
Yes
|
Output short circuit protection
|
The power supply will not broken after long time output short-circuit, remove the short-circuit, the power can recover work
|
Over temperature protection
|
/
|
Other Functions:
|
Environmental Features
|
Working Temperature, Humidity
|
-20~+40℃@100%LOAD, +60℃@60%LOAD, 20%~90%RH
|
Storage Temperature, Humidity
|
-20~+85℃ , 10%~95%RH
|
Heating Way
|
Auto
|
Safety and EMC standard
|
Safety Standard
|
UL 60950 Standard
|
High-voltage Holding Test
|
I/P-O/P: 3KV AC, 10mA,60S
|
Insulation resistance
|
I/P-O/P: 500VAC 100MΩ
|
reliability
|
MTBF
|
MIL-HDBK-217F standard, full load, 25℃, more than 30000h
|
RJ-45 PIN Function
|
RJ-45 Input (Data Only)
|
RJ-45 Output (Data & Power)
|
Pin
|
Symbol
|
Description
|
Symbol
|
Description
|
1
|
TX_D1+
|
Tranceive Data+
|
TX_D1+
|
Tranceive Data+
|
2
|
TX_D1-
|
Tranceive Data-
|
TX_D1-
|
Tranceive Data-
|
3
|
RX_D2+
|
Receive Data+
|
RX_D2+
|
Receive Data+
|
4
|
BI_D3+
|
Bi-directional Data+
|
BI_D3+
|
DC power(+) & Bi-directional Data+
|
5
|
BI_D3-
|
Bi-directional Data-
|
BI_D3-
|
DC power(+) & Bi-directional Data-
|
6
|
RX_D2-
|
Receive Data-
|
RX_D2-
|
Receive Data-
|
7
|
BI_D4+
|
Bi-directional Data+
|
BI_D4+
|
DC power(-) & Bi-directional Data+
|
8
|
BI_D4-
|
Bi-directional Data-
|
BI_D4-
|
DC power(-) & Bi-directional Data-
|
Other specification
|
Weight
|
170±20g
|
Size
|
83mm*55mm*47mm
|
Remark
|
1, All the data is recorded by the test with Input 220VAC, rating load, 25 Degree working temperature, 70% Humidity.
2, Precision include setting error, Line change rate, load change rate, etc.
3, Ripple Wave Test: Use 30cm cable to connect the power and the load, the load is parallel connected with 0.1uf and 47uf capacitors, use 20M OSC test the load part to get the result.
4, Line Regulation: Under rating load, the test is based on the low input voltage change to high input voltage.
5, Load Regulation: The test is based on the change between the 0 Load and 100% load.
|
|
|
|
|
|
|
|
|
|